WIKA manufactures the model PG28 per EN 837-1 both in the “S1” version and in the “S3” safety version. The safety version is made up of a non-splintering window, a solid baffle wall between measuring system and dial and a blow-out back. In the event of a failure, the operator is protected at the front side, as media or components can only be ejected via the back of the case.
■ Wetted parts from Hastelloy C276
■ Excellent resistance against corrosive media such as sulphuric acid, nitric acid, chlorine gas etc.
■ Also available as safety version “S3” per EN 837-1
■ Scale ranges from 0 … 0.6 to 0 … 700 bar [0 … 10 to 0 … 10,000 psi]
■ With case filling for applications with high dynamic pressure loads and vibrations
■ For gaseous and liquid aggressive media that are not highly viscous or crystallising, also in aggressive environments
■ Oil and gas industry, chemical and petrochemical industries